Portable Diagnostic AudiometerType : 270
Specification :
▪ | Frequency range | ||
Air Conduction range | : | 0.125, 0.25, 0.5, 0.75, 1.15, 2, 3, 4, 6, 8 kHz | |
Bone Conduction | : | 0.25, 0.5, 0.75, 1.15, 2, 3, 4, 6, 8 | |
Frequency accuracy | : | <1% | |
Distortion | : | <2% | |
Test method | : | Continuous, interrupted, pulsed, warble | |
▪ | Output level range | ||
Air Conduction range | : | -10 dBHL to 120 dBHL ±3dB | |
Bone Conduction | : | -10 dBHL to 70 dBHL ±3dB | |
Output level step | : | 2.5 / 5dB | |
▪ | Masking | ||
Masking | : | Norrowband and speech weighted noise | |
Output | : | Headphones, insert earphone or insert masker | |
Insert masking output | : | 90dBHL max (250-4 kHz) | |
▪ | Speech input | : | MP3 or CD input or live speech |
▪ | Freefield | ||
Output level range (FF) | : | Up to 90 dB | |
No of loudspeaker | : | 2 | |
▪ | Special tests | ||
Overthreshold tests | : | Stenger test, ABLB (Fowler), SISI | |
▪ | Communication | ||
Talk over | : | Integrated or external monitor headset | |
Talk back | : | External microphone | |
▪ | Data management | ||
Internal database | : | 12 audiograms | |
Optional printer | : | Thermal printer | |
Data transfer | : | Via USB to Amplisuite, NOAH, | |
OtoAccess® and other EMR system | |||
▪ | Physical data | ||
Display | : | 2 lines of 24 characters | |
Power | : | 240Vac 50-60Hz | |
Dimensions | : | (L x W x H): 355 x 230 x 50mm | |
Weight | : | 1540 g / 330 lbs | |
▪ | Safety and standard | ||
Type | : | Audiometer Type 3BE/Type 2 | |
Safety | : | IEC 60601-1 (plus UL, CSA & EN deviation | |
EMC | : | IEC 60601-1-2 | |
Performance | : | IEC 60645-1/ANSI S3.6 | |
CE Mark | : | Complies to EU Medical Device | |
Regulation (MDR 2017/745) | |||
▪ | Complete unit | : | Main units + Audiocups |
: | Standard audiometric headset | ||
: | Bone conduction headset | ||
: | Patient response switch | ||
: | Audiogram cards (50) | ||
: | Power supply with country adaptors | ||
: | Carry case | ||
: | USB stick (manuals, audiometry module | ||
for NOAH and Amplisuite software) |
-
CO2 Incubator 160L - Type : TS-160 | TSite
-
Paket Reagensia BMHP Surveilans Kualitas Air Minum Rumah Tangga dan Pangan KAMRT-01AR
-
Just Jump or Run Meter | Alat Mrngukur Lompat Manusia
-
Balance Ability Measuring Equipment Model : TKK-5407a Triple Sensor
-
Digital Vertical Jump Meter - TKK.5415 Jump-DF
-
Portable Lux Meter LD 8911B Brand : Leeder
-
Vertical Pressure Steam Autoclave Type : VA-SD Ukuran 35 L , 50 L
-
Heat Stress WBGT Meter Type : TM-288 | Alat Uji Ukur WBGT
-
Heat Stress WBGT Meter | Type : TM-188D | Alat Ukur WBGT
-
Medical Skinfold Caliper - Alat Mengukur Ketebalan Kulit Manusia